Mobile and stationary conditioning units
Stationary oil supply
- Tailored module for stationary application (wall mounted),
- Numeric control of pressure/flow-rate/temperature,
- Integrated oil reservoir with bi-cyclone defoamer,
- Optional: specific modifications for race-car engines,
- System for fast oil changes, level indicator,
- safety system to prevent over-filling,
- Temperature control: +30 … +150 °C, ± 1 K,
- Rated power for heating/cooling: 12/150 kW,
- Pressure control: 0 … 12 bar (relative), ± 10 mbar,
- Flow-rate: max. 120 l × min-1,
- Set-point transmitter: digital via CAN-Bus/PROFIBUS DP from remote panel/PC-based control system,
- Dimension: 1.4 × 1.5 × 1.0 m (L × W × H),
- Weight: 220 kg.
Mobile oil supply
- Tailored module for mobile application,
- Numeric control for pressure/flow-rate/temperature,
- System for fast oil changes, level indicator, safety system to prevent over-filling,
- Temperature control: +30 … +150 °C, ± 1 K,
- Rated power for heating/cooling : 18/200 kW,
- Pressure control: 0 … 12 bar (relative ), ± 10 mbar,
- Flow-rate: max. 200 l × min-1,
- Set-point transmitter: digital via CAN-Bus/PROFIBUS DP from remote panel/PC-based control system,
- Optional: integrated oil reservoir with cyclone defoamer,
- Optional: specific modifications for race-car engines,
- Dimension: 1.4 × 1.0 × 2.0 m ( L × W × H),
- Weight: 250 kg.
Mobile coolant supply
- Tailored module for mobile application,
- Numeric control of pressure/flow-rate/temperature,
- Temperature control: +30 … +120 °C, ± 1 K,
- Rated power for heating/cooling : 25/200 kW,
- Pressure control: 0 … 3 bar (relative), ± 10 mbar,
- Flow-rate: max. 400 l × min-1,
- Water inlet/outlet: DIN-flanges 2“, DIN2632 PN16,
- Automatic air vent, level indicator, safety system,
- Set-point transmitter: digital via CAN-Bus/PROFIBUS DP from remote panel/PC-based control system,
- Modular frame/building kit system,
- Removable coverings with acoustic insulation,
- Dimension: 1.4 × 1.0 × 2.0 m (L × W × H),
- Weight: 250 kg.
Stationary coolant supply
- Tailored module for stationary application (wall mounted),
- Numeric control of pressure/flow-rate/temperature,
- Temperature control: +30 … +120 °C, ± 1 K,
- Rated power for heating/cooling: 12/150 kW,
- Pressure control: 0 … 3 bar (relative), ± 10 mbar,
- Flow-rate: max. 180 l × min-1,
- Water inlet/outlet: DIN-flanges 1 1/2“, DIN2632 PN16,
- Automatic air vent, level indicator, safety system,
- Set-point transmitter: digital via CAN-Bus/PROFIBUS DP from remote panel/ PC-based control system,
- Welded steel frame,
- Removable coverings with acoustic insulation,
- Dimension: 1.4 × 1.5 × 1.0 m (L × W × H),
- Weight: 180 kg.
Intake air conditioning
- Tailored module for stationary application (foot mounted),
- Particular for high sophisticated single-cylinder test objects,
- Numeric control for pressure/temperature/humidity of intake air,
- High precision air-flow measurement,
- Set-point transmitter digital via CAN-Bus/PROFIBUS DP,
- Temperature control: +30 … +90 °C, ± 1 K,
- Pressure control: 0 … 3 bar (absolute), ± 10 mbar,
- Humidity: 35 … 95 % r. H.,
- Air flow: max. 260 Nm³/h,
- Easy to service design,
- Optional: noise damping package,
- Dimension: 3.0 × 1.5 × 4.0 m (L × W × H),
- Weight: 750 kg.