End-of-line testing
Performance test bench 800 kW
- High-speed performance tests end-of-line,
- Two railway axle drives in back-to-back position,
- Input power (AC-drive): max. 90 kW,
- Speed range: 0 … max. 2,000 r. p. m. ,
- Accuracy of speed controller: ± 1 r. p. m.,
- Internal cramping power: max. 800 kW,
- Internal torque: max. 20,000 Nm,
- Repeatability of torque measurement system: ± 30 Nm,
- King pin clamping range: 100 … max. 150 mm,
- Fully PLC controlled, HMI: Win-PC based,
- Free programmable for tailored test procedures,
- Tailored swivel boom,
measurement of temperature (16 channels)/vibration (6 channels),
- Ready for unmanned service,
- Ethernet interface.
Performance test bench 1200 kW
- High-speed performance tests end-of-line,
- Two railway axle drives in back-to-back position,
- Input power (AC-drive): max. 90 kW,
- Speed range: 0 … max. 2,000 r. p. m. ,
- Accuracy of speed controller: ± 1 r. p. m.,
- Internal cramping power: max. 1,200 kW,
- Internal torque: max. 20,000 Nm,
- Repeatability of torque measurement system: ± 30 Nm,
- King pin clamping range: min. 100 … max. 150 mm,
- Fully PLC controlled, HMI: Win-PC based,
- Free programmable for tailored test procedures,
- Tailored swivel boom, measurement of temperature (16 channels)/vibration (6 channels),
- Ready for unmanned service,
- Ethernet interface.
Extension for low-floor axle drive testing
- Full-load performance tests end-of-line,
- Coupling device for quick application of two railway low-floor axle drives in back-to-back position,
- Input speed range: 0 … max. 4,000 r. p. m. ,
- Accuracy of speed controller: ± 1 r. p. m.,
- Internal cramping power: max. 100 kW,
- Internal torque: max. 1,900 Nm,
- Repeatability of torque measurement system: ± 30 Nm,
- Fully PLC controlled, HMI: Win-PC based,
- Tailored test procedures,
- Measurement of rotaional speed, output torque, temperature (8 channels)/vibration (6 channels),
- Documentation: test record print out (pdf),
- Local data storage.